Internet Archive BookReader IS 10262: Guidelines for concrete mix design proportioning Internet Archive BookReader IS 10262: Guidelines for concrete mix design. (IS ) The new code explains the mix proportioning procedure using a typical mix design problem. Table 1 shows that the basic data required for new BIS method is similar to that of the ACI method of mix design. The new BIS is applicable to ordinary and standard concrete grades only.6 The durability requirements, limitations on. Earlier title 'Recommendedguidelines for concrete mix design'. B) The applicability ofthe standard has been specified for ordinary and standard concrete grades only. C) Various requirements have been modified in line with the requirements of IS 456: 2000 'Plain and reinforced concrete - Code ofpractice (fourth revision)'. Is code pdf download. Concrete mix proportioning as per IS – The Indian final code on concrete mix proportioning in December. Code method of mix design (IS: 10262 – 1982) and Indian Road. Congress (IRC) – 44 methods. May 07, 2018 How To Do Mix Design Of Concrete As Per IS Code 10262 SSD Condition Mix Design Of Concrete Moisture Content Condition https://youtu.be/6K1H0tYz8A.
- Concrete Mix Design Code Is 10262 Free Download
- Concrete Mix Design Code Is 10262 Pdf Free Download
- Concrete Mix Design Code Is 10262 Free Download For Windows 7
- Concrete Mix Design Code Is 10262 Free Download 2017
Concrete Mix Design Code Is 10262 Free Download
Installer for the latest version (v1.92.0)
The current version for the Concrete Quality package is 1.92.0. All users with version 1.80.x and previous are required to install this update to continue using the subscription services. Users with version 1.90 and following don’t need to take any actions, Concrete Quality will automatically update to the latest version upon starting.
You can download it with the link below, for both new installations and to upgrade your current version. The first time you run this version, even for updates, you’ll need to select your language and the optional packages you want to install.
This installer lets you choose your language and optional packages during installation.
You will need administrator privileges for your computer to complete the installation, specially if any of the required pre-requisites needs to be installed. Check with your IT department if you need special permissions to install.
If your Windows version is not compatible install the latest Windows Service Pack. Don’t install or try to run the application within a network (shared) drive or folder.
If you have problems installing or running the application, please contact us.
If you already have Concrete Quality installed and running use the link above to update to the latest version. You will not lose existing information, but we recommend that you synchronize with the server before performing any updates.
If you need help installing the application you can see Installation tutorial.
Troubleshooting
In case you cannot install Concrete Quality, please try to install the necessary components:
- .NET Framework: version 4.5.1
This installer includes the minimal required pre-requisites for the application to work: .NET Framework 4.5.1. It will be installed automatically if necessary, though its installation may fail in some cases. You will not be able to run Concrete Quality if this component is not correctly installed.
You require administrator privileges for your computer to install these components. The firewall must not reject incoming and outgoing connections for the endpoint https://cqserver.concrete-quality.com/PROD/syncro.svc. Ask your IT department for help regarding this.
If your Windows version is not compatible install the latest Windows Service Pack. Newer Windows versions include these components as a part of the standard build.
If you still have problems installing or running the application, please contact us.
Changes in the latest version
The new version 1.92.0 includes many performance improvements and new features, such as:
- Automatic updates! This version is the last one you’ll need to install, from now on Concrete Quality will update itself automatically.
- New! Full translations into Russian language.
- New! Test specimens crushing scheduler across all workgroups in the Global Vision section.
- New! R&D lab feature to schedule lab mixes and check which ones are pending for all workgroups in the Global Vision section.
- General fixes and various upgrades.
Compatible operating systems
The Concrete Quality software package works under all Windows versions that support .NET Framework 4.5.1 or higher:
Windows 10; Windows 8 & 8.1; Windows 7; Windows 7 Service Pack 1; Windows Server 2003 Service Pack 2; Windows Server 2008; Windows Server 2008 R2; Windows Server 2008 R2 SP1; Windows Vista Service Pack 1. Windows XP is no longer supported.
Starting at Windows 8 the .NET Framework component is included as standard, so it’s not necessary to install it to run Concrete Quality. It might still be necessary to install the SQL Server CE 4.0 SP1 component.
The Concrete Quality package is not compatible with Mac or other operating systems (Unix, Linux, etc), nor is supported in mobile devices (tablets, smartphones, etc.). For mobile access you have the Field Test feature.
Download installation requirements
In order to run the Concrete Quality package the Microsoft .NET Framework components are needed, which extend Windows functionality. These components are provided directly by Microsoft and are included in the full installer. They will be installed only if necessary.
Concrete Mix Design Code Is 10262 Pdf Free Download
Find below the links for the individual components installers, in case you need them.
.NET Framework
To run Concrete Quality you need the .NET Framework 4.5.1 or higher. You can find it here:
Concrete Mix Design Code Is 10262 Free Download For Windows 7
.NET Framework 4.5.1 (both 32 & 64 bits)
- Free download without registration
- Unlimited functionality
- No cancellation required
- Pay only for optional services
- FREE! Expert plan trial for one month
Register a new user
To register a new user open Concrete Quality and use the right panel named “I’m new here” (light blue color) in the log in screen.
This Indian Standard was adopted by the Indian Standards Institution on 30 July 1982, after the draft finalized by the Cement and Concrete Sectional Committee had been approved by the Civil Engineering Division Council. Considerable need has been felt for formulating standard recommendations for guidelines on proportioning of concrete mixes. The need has been further emphasized by the importance given to design mix concrete according to IS : 456-1978*. Having recognized this need, Cement and Concrete Sectional Committee decided to evolve a standard recommended guidelines for concrete mix design. 043 The proportioning of concrete mixes consists of determination of the quantities of respective ingredients necessary to produce concrete having adequate, but not excessive, workability and strength for the particular loading and durability for the exposure to which it will be subjected. Emphasis is laid on making the most economical use of available materials so as to produce concrete of the required attributes at the minimum cost, Concrete has to be of satisfactory quality in both the fresh and hardened states. The task of proportioning concrete mixes is accomplished by the use of certain established relationships which afford reasonably accurate guidance for selecting the best combination of ingredients so as to achieve the desirable properties of the fresh and hardened concrete. Out of all the physical characteristics of concrete, compressive strength is often taken as an index of its quality in terms of durability, impermeability and watertightness and is easily measurable. Therefore, the mix design is generally carried out for a particular compressive strength of concrete, coupled with adequate workability, so that the fresh concrete can be properly placed and compacted. In addition, the mix proportions are also checked against the requirements of adequate durability for the type of exposure condition anticipated in service. The basic assumption made in mix design is that the comprrssive strength of workable concrete is, by and large, governed by the watercement ratio. Another most convenient relationship applicable to normal concretes is that for a given type, shape, size and grading of aggregates, the amount of water determines its workability. However, there are various other factors which affect the properties of concrete, for example, the quality and quantity of cement, water and aggregates; batching; transportation; placing; compaction; curing; etc. Therefore, the specific relationships that are used in proportioning concrete mixes should be considered only as a basis for trial, subject to modifications in the light of experience as well as for the particular materials used at the site in each case. This standard does not debar the adoption of any other accepted methods of mix design. For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in accordance with IS : 2-1960. The number of significant places retained in the rounded off value should be the same as that of the specified value in this standard.
Download IS 10262-1982 Code Book in PDF format using the provided download link:
Disclaimer:
Concrete Mix Design Code Is 10262 Free Download 2017
The code book provided on this website is neither created nor scanned by us, it’s downloaded from the internet and provided purely for educational purpose only. If you can afford this book, kindly purchase the book.